Progress in OCT-based Through Silicon Via (TSV) metrology

2019 
We report on progress in Time-Domain OCT (optical coherence tomography) applied to TSV (vertical interconnect accesses in silicon, enabling stacking of devices). Transitioning from the common scalar approach to an electromagnetic one, and combining it with a damped least squares approach, we enhance the accuracy of TSV height measurements.