logo
    A Microfluidic Concentration Gradient Maker with Tunable Concentration Profiles by Changing Feed Flow Rate Ratios
    10
    Citation
    30
    Reference
    10
    Related Paper
    Citation Trend
    Abstract:
    Microfluidic chips—in which chemical or biological fluid samples are mixed into linear or nonlinear concentration distribution profiles—have generated enormous enthusiasm of their ability to develop patterns for drug release and their potential toxicology applications. These microfluidic devices have untapped potential for varying concentration patterns by the use of one single device or by easy-to-operate procedures. To address this challenge, we developed a soft-lithography-fabricated microfluidic platform that enabled one single device to be used as a concentration maker, which could generate linear, bell-type, or even S-type concentration profiles by tuning the feed flow rate ratios of each independent inlet. Here, we present an FFRR (feed flow rate ratio) adjustment approach to generate tens of types of concentration gradient profiles with one single device. To demonstrate the advantages of this approach, we used a Christmas-tree-like microfluidic chip as the demo. Its performance was analyzed using numerical simulation models and experimental investigations, and it showed an excellent time response (~10 s). With on-demand flow rate ratios, the FFRR microfluidic device could be used for many lab-on-a-chip applications where flexible concentration profiles are required for analysis.
    Keywords:
    Soft Lithography
    Flow focusing
    Microfluidic chip
    Concentration gradient
    Multiplexed or parallelised droplet microfluidic systems allow for increased throughput in the production of emulsions and microparticles, while maintaining a small footprint and utilising minimal ancillary equipment. The current paper demonstrates the design and fabrication of a multiplexed microfluidic system for producing biocatalytic microspheres. The microfluidic system consists of an array of 10 parallel microfluidic circuits, for simultaneous operation to demonstrate increased production throughput. The flow distribution was achieved using a principle of reservoirs supplying individual microfluidic circuits. The microfluidic devices were fabricated in poly (dimethylsiloxane) (PDMS) using soft lithography techniques. The consistency of the flow distribution was determined by measuring the size variations of the microspheres produced. The coefficient of variation of the particles was determined to be 9%, an indication of consistent particle formation and good flow distribution between the 10 microfluidic circuits.
    Soft Lithography
    Flow focusing
    Footprint
    Citations (0)
    This chapter contains sections titled: Introduction Microfluidic Devices for Concentration Gradients Electrochemistry and Microfluidics PDMS and Electrochemistry Optics and Microfluidics Unconventional Soft Lithographic Fabrication of Optical Sensors Acknowledgments References
    Soft Lithography
    Lab-on-a-chip technology achieves a reduction of sample and reagent volume and automates complex laboratory processes. Here, we present the implementation of cell assays on a microfluidic platform using disposable microfluidic chips. The applications are based on the controlled movement of cells by pressure-driven flow inside networks of microfluidic channels. Cells are hydrodynamically focused and pass the fluorescence detector in single file. Initial applications are the determination of protein expression and apoptosis parameters. The microfluidic system allows unattended measurement of six samples per chip. Results obtained with the microfluidic chips showed good correlation with data obtained using a standard flow cytometer.
    Microfluidic chip
    Lab-on-a-Chip
    We develop a simple method to determine the microdroplet features in a microfluidic chip fabricated by conventional soft lithography. Different sizes of microdroplets are generated through a typical microfluidic T-junction by adjusting the flow rates of the two immiscible liquids. Droplet size and content can be determined by monitoring the optofluidic signals reflected at the fluid–polydimethylsiloxane (PDMS) interface. The demonstrated droplet characterization system can be readily integrated with other microfluidic networks, making it promising for biochemical and biosensing applications.
    Polydimethylsiloxane
    Soft Lithography
    Characterization
    Optofluidics
    Lab-on-a-Chip
    Microfluidic chip
    Citations (13)
    Microfluidic chips—in which chemical or biological fluid samples are mixed into linear or nonlinear concentration distribution profiles—have generated enormous enthusiasm of their ability to develop patterns for drug release and their potential toxicology applications. These microfluidic devices have untapped potential for varying concentration patterns by the use of one single device or by easy-to-operate procedures. To address this challenge, we developed a soft-lithography-fabricated microfluidic platform that enabled one single device to be used as a concentration maker, which could generate linear, bell-type, or even S-type concentration profiles by tuning the feed flow rate ratios of each independent inlet. Here, we present an FFRR (feed flow rate ratio) adjustment approach to generate tens of types of concentration gradient profiles with one single device. To demonstrate the advantages of this approach, we used a Christmas-tree-like microfluidic chip as the demo. Its performance was analyzed using numerical simulation models and experimental investigations, and it showed an excellent time response (~10 s). With on-demand flow rate ratios, the FFRR microfluidic device could be used for many lab-on-a-chip applications where flexible concentration profiles are required for analysis.
    Soft Lithography
    Flow focusing
    Microfluidic chip
    Concentration gradient
    Citations (10)
    The authors report the design and implementation of an electrorheological (ER) fluid-actuated microfluidic pump, with programmable digital control. Our microfluidic pump has a multilayered structure fabricated on polydimethylsiloxane by soft-lithographic technique. The ER microfluidic pump exhibits good performance at high pumping frequencies and uniform liquid flow characteristics. It can be easily integrated with other microfluidic components. The programmable control also gives the device flexibility in its operations.
    Polydimethylsiloxane
    Soft Lithography
    Electrorheological fluid
    Flow Control
    Digital Microfluidics
    Fluidics
    Citations (43)