Magnetostriction of grain oriented Si-Fe and its domain model

2011 
Transformer noise has been drawing more and more attentions recently. One of the main causes of transformer noise is magnetostriction of grain oriented electrical steel sheets. Magnetostrictions perpendicular to the rolling direction should also be focused in addition to those to the rolling direction, because magnetic flux flows out of the rolling directions especially around T-joint parts of 3-phase transformers. In this paper, magnetostrictions of high permeability grain oriented electrical steel sheets to the both directions were measured with a Dopplervibrometer and rationalized by magnetic domain models. Streszczenie. .Szumy generowane przez transformatory są obecnie analizowane coraz bardziej szczegolowo. Glownym ich źrodlem jest magnetostrykcja blach zorientowanych. Magnetostrykcja prostopadla do kierunku walcowania powinna byc takze brana pod uwage poniewaz strumien magnetyczny nie zawsze jest w kierunku walcowania. W artykule przeanalizowano magnetostrykcje blach zorientowanych w obu kierunkach uzywając wibrometr Dopplera. (Magnetostrykcja blach anizotropowych SiFe i jej model domenowy)