Design and development of a trace contaminant removal canister for Spacelab

1979 
The paper describes the overall approach used by NASA-MSFC to design and develop a trace contaminant removal canister for Spacelab. The elements of this approach include the establishment of a trace contaminant load model, analysis and testing to define a preliminary design, development testing to verify the adequacy of the selected design, and testing to define a suitable canister location in the transfer tunnel ventilation system. The canister utilizes a catalyst material which is effective in removing carbon monoxide at room temperature, as well as plain and acid treated charcoal. The canister alone will control all contaminants in the load model below their maximum allowable concentration (MAC) levels without assistance from the baseline environmental control system (ECS) except for methyl alcohol and ammonia.