Temperature and Lifetime Measurements in the SSX Wind Tunnel

2018 
We describe ion and electron temperature measurements in the Swarthmore Spheromak Experiment (SSX) MHD wind tunnel with the goal of understanding limitations on the lifetime of our Taylor-state plasma. A simple model based on the equilibrium eigenvalue and Spitzer resistivity predicted the lifetime satisfactorily during the first phase of the plasma evolution. We measured an average T e along a chord by taking the ratio of the C I I I 97.7 nm to C I V 155 nm line intensities using a vacuum ultraviolet (VUV) monochromator. We also recorded local measurements of T e and n e using a double Langmuir probe in order to inform our interpretation of the VUV data. Our results indicated that the plasma decayed inductively during a large part of the evolution. Ion Doppler spectroscopy measurements suggested that ions cooled more slowly than would be expected from thermal equilibration with the electrons, which maintained a constant temperature throughout the lifetime of the plasma.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    26
    References
    8
    Citations
    NaN
    KQI
    []