Abstract Introduction Circulating microvesicles (MV) can be analysed using a number of different techniques. The aim of this study was to evaluate the correlation between functional procoagulant based assays including thrombin generation, factor Xa activation test (XaCT), and phosphatidylserine factor Xa-activity by ELISA with optical MV enumeration by flow cytometry and nanoparticle tracking analysis. Methods Citrated blood samples were collected from 60 healthy volunteer blood donors after informed consent. Platelet free plasma was prepared using a standardized published protocol. MV subsets were enumerated by flow cytometry (BDFACS Canto) after staining with specific antibodies for platelets (CD41), endothelial cells (CD105), red cells (CD235) monocytes (CD14), tissue factor (CD142) and for phosphatidylserine expression by binding to annexin V. A standardized protocol using counting beads was employed. Nanotracking analysis was performed on both scatter and fluorescent settings after MV staining with quantum dot stain, Qdot 655. Procoagulant function was assessed by the XaCT assay on an automated coagulation analyser and by thrombin generation assay measuring endogenous thrombin potential (ETP), lagtime, peak (PEAK) and time to peak (ttPEAK) using a Calibrated Automated Thrombogram (CAT). The statistical analysis was carried out with Statistica 12 software using non-parametric tests (Spearman rank order correlations, with significance set at p  Results In normal healthy subjects, thrombin generation parameters correlated with levels of MV measured by flow cytometry. ETP, lagtime, ttPEAK and PEAK correlated with MV expressing phosphatidylserine (r s, Spearman rank order correlation was 0.29, 0.40, 0.31 and 0.34 respectively, p  s was 0.29, 0.40, 0.31 and 0.34 respectively, p  s, was 0.35,0.30 and 0.3, respectively, p  s, was − 0.34 and − 0.30 respectively, p  s  = 0.42 for both, p  s = 0.27, p  Conclusions Thrombin generation and flow cytometry for phosphatidylserine or tissue factor expressing MV correlate well as markers for procoagulant activity. A combination of optical or non-optical enumeration as well as functional methods may be required for a complete profiling of circulating MV.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    36
    References
    15
    Citations
    NaN
    KQI
    []