language-icon Old Web
English
Sign In

A new MEMS wafer probe card

1997 
This work presents a new type of wafer probe card consisting of an array of microcantilevers actuated by bimorph heating to make contact with the contact pads on a device chip during wafer-stage testing. The microcantilevers are meant to be operated either in air or in vacuum. Bending action is created through Joule heating of a bimorph film element on the cantilever. The deflection efficiency d/spl delta//dP ranges from 5.8 to 9.6 /spl mu/m/mW (depending on lever parameters), the force efficiency dF/dP ranges from 1.4 to 5.5 /spl mu/N/mW; maximum controllable (reversible) deflection is in the range of 150 /spl mu/m, and contact resistance to a gold pad is approximately 1 /spl Omega/.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    5
    References
    21
    Citations
    NaN
    KQI
    []