Subcutaneous adipose tissue response to a non‐invasive hyperthermic treatment using a 1,060 nm laser

2017 
Background We postulated that a hyperthermic treatment using a 1,060 nm laser can cause a controlled adipocyte injury resulting in non-invasive fat reduction. This three-part study identified treatment parameters for a safe and tolerable treatment, demonstrated short- and long-term tissue response, and assessed the potential of this treatment for non-invasive fat reduction. Methods In vivo temperature measurements were conducted prior to abdominoplasty via a thermal camera (for surface readings) and thermocouple needle (for subcutaneous readings). Short- and long-term tissue response was evaluated on the abdomen immediately post to 6 months post a 1,060 nm laser treatment. Laser dosage was varied to identify safe and effective parameters for fat reduction. Tissue biopsies for hematoxylin/eosin (HE four patients receiving laser treatment to one flank and cryolipolysis on the other, and two patients receiving laser treatment on one side with the other side as an untreated control. Efficacy measurements included ultrasound measurement of fat thickness at baseline, 2, 3, and 6 months; Magnetic Resonance Imaging (MRI) to calculate fat volume at baseline, 3 and 6 months; and blinded photograph evaluation at baseline, 1, 2, 3, and 6 months. Results In vivo temperature measurements demonstrated that the hyperthermic temperature target (42–47°C) can be achieved and maintained in subcutaneous adipose tissue via a 1,060 nm laser in conjunction with surface cooling. Short- and long-term tissue responses were evaluated by tissue histology up to 6 months following treatment. Histological changes included inflammation, followed by macrophage infiltration starting at approximately 2 weeks, with evacuation of cellular debris completed by approximately 6 months. Clinical results demonstrated average fat thickness reduction at 14%, 18%, and 18% at 2, 3, and 6 months, respectively. Average fat volume reduction measured by MRI at 3 and 6 months was 24% and 21%, respectively. Blinded photo evaluation showed improvement starting at 1-month post-treatment and was maintained at 6 months. Adverse events were rare and included mild tenderness that resolved by 1-week post-treatment. Conclusion Parameters were identified that selectively injure and reduce adipocytes in subcutaneous tissue using a 1,060 nm externally applied laser. The treatment had an excellent safety profile and was well tolerated. The clinical study demonstrated that a 1,060 nm hyperthermic laser treatment for non-invasive fat reduction can be safe and effective. Lasers Surg. Med. 9999:XX–XX, 2016. © 2016 Wiley Periodicals, Inc.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    17
    References
    28
    Citations
    NaN
    KQI
    []