Fast atomic line filter/field ionization detector

1990 
An experimental demonstration of a fast atomic line filter/field ionization detector (FALF/FID) is presented. The FALF/FID detects incoming signal photons by resonant absorption in an atomic vapor cell containing a strong electric field. Excited atoms are electric-field ionized after further excitation to a Stark-shifted Rydberg level by a pump laser tuned to a resonance in the ionization spectrum, providing an observed enhancement in the ionization rate of ten times over the continuum ionization threshold. Preliminary measurements of time response ( 25%) indicate that with optimization the FALF/FID will provide high quantum efficiency, fast time response, and narrow-linewidth detection.