Effects of sphere size and injection site on regional cerebral blood flow measurements.

1983 
Regional cerebral blood flows and shunting of microspheres with four different sizes (9,12, 16 and 25 microns) into the superior sagittal sinus were determined in twelve dogs. Venous blood was collected from the superior sagittal sinus for 120 min after the injection of microspheres, and the dogs were then sacrificed immediately. Results on blood flow measurements and venous shunting determinations were similar between left ventricular and left atrial injections. Blood flows measured by 12, 16 and 25 microns spheres were comparable in various brain tissues, except the choroid plexus. 9 microns spheres underestimated blood flows in all regions studied: by 13-19 percent in the cerebral cortex, midbrain, brain stem and cerebellum, by 34-42 percent in the cortical white matter, corpus callosum and cervical cord, and by 64-81 percent in pituitary gland and choroid plexus. These results probably reflect regional difference in microvascular architecture. Venous shunting of 9, 12, 16 and 25 microns spheres during...