Physical properties of MTA Fillapex sealer.
2013
Abstract Introduction The aim of this study was to evaluate and compare several physicochemical properties including working and setting times, flow, solubility, and water absorption of a recent calcium silicate–based sealer (MTA Fillapex; Angelus, Londrina, Brazil) and an epoxy resin–based sealer (AH Plus; Dentsply, Konstanz, Germany). Methods The materials were handled following the manufacturer's instructions. The working time and flow were tested according to ISO 6876:2001 and the setting time according to American Society for Testing and Materials C266. For solubility and water absorption tests, the materials were placed into polyvinyl chloride molds (8 × 1.6 mm). The samples ( n = 10 for each material and test) were placed in a cylindrical polystyrene-sealed container with 20 mL deionized water at 37°C. At 1, 7, 14, and 28 days, the samples were removed from the solutions and blotted dry for solubility and water absorption tests. The data were analyzed using 1-way analysis of variance with the Tukey test ( P Results MTA Fillapex showed the lowest values of flow, working and setting times, solubility, and water absorption ( P P Conclusions MTA Fillapex showed suitable physical properties to be used as an endodontic sealer.