Investigation of EUV pellicle mechanical stress within EUV pod

2021 
Extreme ultraviolet (EUV) pellicle has been widely used to control the defectivity of EUV mask out of airborne debris. The EUV mask equipped with pellicle is typically stored within a EUV inner pod (EIP) until use. However, such pellicle is easily deformed due to its structural weakness, the risk of thermal stress and so on, thereby altering its transmission as well as impacting the yield of EUV fabrication. Since the activity of EUV pellicle alone is comprehensively studied, the exploration of pellicle mechanical stress within EIP is relatively less addressed. Here, we present an emerging approach via a chromatic confocal sensor to investigate the above issue. The chromatic sensor was utilized to detect the surface of pellicle based on the reflected light wavelength with a 22 nm axial resolution. A conductance tester was utilized to simulate the pump and vent characteristics, according to ASML and core EUV scanners. During the pump/vent cycle (from atmospheric pressure to 5 Pa and vice versa), the EUV pellicle was deflected from -400 μm to 200 μm. We further analyzed the stress of deformed pellicle by both numerical simulation and theoretical calculation. Interestingly, the graphene-mediated pellicle revealed a more stiffer activity than other material-based pellicles (such as poly-silicon, SiC and Si3N4) under a range of pressure difference (0 to 10 Pa). Taken together, the proposed approach has been successfully demonstrated to enable real-time examination of EUV pellicle activity within EIP, which should be capable for worldwide EUV mask cores.