Abstract Due to frequent and often severe lung affections caused by COVID-19, murine models of acute respiratory distress syndrome (ARDS) are increasingly used in experimental lung research. The one induced by a single lipopolysaccharide (LPS) exposure is practical. However, whether it is preferable to administer LPS intranasally or intratracheally remains an open question. Herein, female C57Bl/6 J mice were exposed intranasally or intratracheally to one dose of either saline or 3 mg/kg of LPS. They were studied 24 h later. The groups treated with LPS, either intranasally or intratracheally, exhibited a pronounced neutrophilic inflammation, signs of lung tissue damage and protein extravasation into the alveoli, and mild lung dysfunction. The magnitude of the response was generally not different between groups exposed intranasally versus intratracheally. However, the variability of some the responses was smaller in the LPS-treated groups exposed intranasally versus intratracheally. Notably, the saline-treated mice exposed intratracheally demonstrated a mild neutrophilic inflammation and alterations of the airway epithelium. We conclude that an intranasal exposure is as effective as an intratracheal exposure in a murine model of ARDS induced by LPS. Additionally, the groups exposed intranasally demonstrated less variability in the responses to LPS and less complications associated with the sham procedure.
Airway hyperresponsiveness often constitutes a primary outcome in respiratory studies in mice. The procedure commonly employs aerosolized challenges, and results are typically reported in terms of bronchoconstrictor concentrations loaded into the nebulizer. Yet, because protocols frequently differ across studies, especially in terms of aerosol generation and delivery, direct study comparisons are difficult. We hypothesized that protocol variations could lead to differences in aerosol delivery efficiency and, consequently, in the dose delivered to the subject, as well as in the response. Thirteen nebulization patterns containing common protocol variations (nebulization time, duty cycle, particle size spectrum, air humidity, and/or ventilation profile) and using increasing concentrations of methacholine and broadband forced oscillations ( flexiVent, SCIREQ, Montreal, Qc, Canada) were created, characterized, and studied in anesthetized naïve A/J mice. A delivered dose estimate calculated from nebulizer-, ventilator-, and subject-specific characteristics was introduced and used to account for protocol variations. Results showed that nebulization protocol variations significantly affected the fraction of aerosol reaching the subject site and the delivered dose, as well as methacholine reactivity and sensitivity in mice. From the protocol variants studied, addition of a slow deep ventilation profile during nebulization was identified as a key factor for optimization of the technique. The study also highlighted sensitivity differences within the lung, as well as the possibility that airway responses could be selectively enhanced by adequate control of nebulizer and ventilator settings. Reporting results in terms of delivered doses represents an important standardizing element for assessment of airway hyperresponsiveness in mice.
The quantification of airway compliance (Caw) is essential to the study of airway alterations in disease models. However, the required measurements of airway pressure and volume are difficult to acquire in mice. We hypothesized that the inflation limb of full-range pressure-volume (PV) curves could be used to quantify Caw, as it contains a segment where only the airway tree is distended. The study objective was to assess the feasibility of the approach by analysis of full-range PV curves previously collected in three mouse models: an elastase model of emphysema, a genetic model spontaneously developing emphysema (leukotriene C4 synthase knockout; LTC4S-KO), and a bleomycin model of lung fibrosis. Attempts to validate results included Caw change relative to respiratory system compliance (ΔCaw/ΔC), the minute work of breathing (mWOB), and the elastance at 20.5 Hz (Ers_20.5) from prior respiratory mechanics measurements in the same subjects. Caw was estimated at 3% of total compliance in healthy mice or 2.3 ± 1 μL/cmH2O (n = 17). The technique detected changes in models of respiratory obstructive and restrictive diseases relative to control mice as well as differences in the two emphysema models studied. The changes in Caw were consistent with those seen in ΔCaw/ΔC, mWOB, or Ers_20.5, with some variations according to the model, as well as with results reported in the literature in humans and mice. Direct Caw measurements in subjects as small as mice could prove useful to further characterize other respiratory disease models associated with airway remodeling or to assess treatment effects.
Pulmonary function has been reported in mice using negative pressure-driven forced expiratory manoeuvres (NPFE) and the forced oscillation technique (FOT). However, both techniques have always been studied using separate cohorts of animals or systems. The objective of this study was to obtain NPFE and FOT measurements at baseline and following bronchoconstriction from a single cohort of mice using a combined system in order to assess both techniques through a refined approach. Groups of allergen- or sham-challenged ovalbumin-sensitized mice that were either vehicle (saline) or drug (dexamethasone 1 mg/kg ip)-treated were studied. Surgically prepared animals were connected to an extended flexiVent system (SCIREQ Inc., Montreal, Canada) permitting NPFE and FOT measurements. Lung function was assessed concomitantly by both techniques at baseline and following doubling concentrations of aerosolized methacholine (MCh; 31.25 - 250 mg/ml). The effect of the NPFE manoeuvre on respiratory mechanics was also studied. The expected exaggerated MCh airway response of allergic mice and its inhibition by dexamethasone were detected by both techniques. We observed significant changes in FOT parameters at either the highest (Ers, H) or the two highest (Rrs, RN, G) MCh concentrations. The flow-volume (F-V) curves obtained following NPFE manoeuvres demonstrated similar MCh concentration-dependent changes. A dexamethasone-sensitive decrease in the area under the flow-volume curve at the highest MCh concentration was observed in the allergic mice. Two of the four NPFE parameters calculated from the F-V curves, FEV0.1 and FEF50, also captured the expected changes but only at the highest MCh concentration. Normalization to baseline improved the sensitivity of NPFE parameters at detecting the exaggerated MCh airway response of allergic mice but had minimal impact on FOT responses. Finally, the combination with FOT allowed us to demonstrate that NPFE induced persistent airway closure that was reversible by deep lung inflation. We conclude that FOT and NPFE can be concurrently assessed in the same cohort of animals to determine airway mechanics and expiratory flow limitation during methacholine responses, and that the combination of the two techniques offers a refined control and an improved reproducibility of the NPFE.
The usefulness of selective inhibitors of type 4 phosphodiesterase (PDE4) in the treatment of inflammation and pulmonary diseases is limited by their side effects: nausea and vomiting. We studied the effect of three structurally diverse PDE4 inhibitors on the vagal nerve afferent and efferent fibers in anesthetized rats. The effects of RS14203, (R)-rolipram, and CT-2450 were evaluated on the von Bezold-Jarisch reflex (vagal afferent fibers) and in a model of vagal electrical stimulation (vagal efferent fibers). All three PDE4 inhibitors were administered at 1, 10, or 100 µg/kg (iv) 15 min prior to the induction of bradycardia by an iv injection of 2-methyl-5-HT (von Bezold-Jarisch reflex) or by vagal electrical stimulation. At 100 µg/kg, RS14203 significantly potentiated the 2-methyl-5-HT response. No statistically significant effects were observed with (R)-rolipram or CT-2450 at the doses studied. RS14203, (R)-rolipram, or CT-2450 (1-100 µg/kg iv) did not affect the bradycardia induced by vagal electrical stimulation. Consequently, our results show that RS14203 selectively facilitates serotoninergic neurotransmission in vagal afferent fibers. The emetic action of RS14203 may be mediated by this mechanism.Key words: PDE4 inhibitors, von Bezold-Jarisch reflex, emesis, vagal afferent and efferent fibres, bradycardia.
Epithelial cells play a critical role in airway inflammation and have the capacity to produce many inflammatory mediators, including bioactive lipids and proinflammatory cytokines. Intracellular levels of cAMP and cGMP are important in the control of inflammatory cell function. These cyclic nucleotides are inactivated via a family of phosphodiesterase (PDE) enzymes, providing a possible site for drug intervention in chronic inflammatory conditions. We studied the expression of PDE activity in an epithelial cell line (A549) and in primary human airway epithelial cells (HAECs). We measured PDE function using specific inhibitors to identify the PDE families present and used RT-PCR to elucidate the expression of PDE isogenes. Both A549 cells and HAECs predominantly expressed PDE4 activity, with lesser PDE1, PDE3, and PDE5 activity. RT-PCR identified HSPDE4A5 and HSPDE4D3 together with HSPDE7. Inhibition of PDE4 and PDE3 reduced secretion by these cells. Epithelial PDE may be an important target for PDE4 inhibitors in the development of the control of asthmatic inflammation, particularly when delivered via the inhaled route.
Airway oscillometry has become the de facto standard for quality assessment of lung physiology in laboratory animals and has demonstrated its usefulness in understanding diseases of small airways. Nowadays, it is seeing extensive use in daily clinical practice and research; however, a question that remains unanswered is how well physiological findings in animals and humans correlate? Methodological and device differences are obvious between animal and human studies. However, all devices deliver an oscillated airflow test signal and output respiratory impedance. In addition, despite analysis differences, there are ways to interpret animal and human oscillometry data to allow suitable comparisons. The potential with oscillometry is its ability to reveal universal features of the respiratory system across species, making translational extrapolation likely to be predictive. This means that oscillometry can thus help determine if an animal model displays the same physiological characteristics as the human disease. Perhaps more importantly, it can also be useful to determine whether an intervention is effective as well as to understand if it affects the desired region of the respiratory system, e.g., the periphery of the lung. Finally, findings in humans can also inform preclinical scientists and give indications as to what type of physiological changes should be observed in animal models to make them relevant as models of human disease. The present article will attempt to demonstrate the potential of oscillometry in respiratory research, an area where the development of novel therapies is plagued with a failure rate higher than in other disease areas.
The usefulness of selective inhibitors of type 4 phosphodiesterase (PDE4) in the treatment of inflammation and pulmonary diseases is limited by their side effects: nausea and vomiting. We studied the effect of three structurally diverse PDE4 inhibitors on the vagal nerve afferent and efferent fibers in anesthetized rats. The effects of RS14203, (R)-rolipram, and CT-2450 were evaluated on the von Bezold-Jarisch reflex (vagal afferent fibers) and in a model of vagal electrical stimulation (vagal efferent fibers). All three PDE4 inhibitors were administered at 1, 10, or 100 microg/kg (iv) 15 min prior to the induction of bradycardia by an iv injection of 2-methyl-5-HT (von Bezold-Jarisch reflex) or by vagal electrical stimulation. At 100 microg/kg, RS14203 significantly potentiated the 2-methyl-5-HT response. No statistically significant effects were observed with (R)-rolipram or CT-2450 at the doses studied. RS14203, (R)-rolipram, or CT-2450 (1-100 microg/kg iv) did not affect the bradycardia induced by vagal electrical stimulation. Consequently, our results show that RS14203 selectively facilitates serotoninergic neurotransmission in vagal afferent fibers. The emetic action of RS14203 may be mediated by this mechanism.