    We carried out an in-vivo and in-vitro evaluation of a new polyamide hollow fiber hemofilter especially designed to operate under conditions of low pressure and low blood flow, such as in continuous arteriovenous hemofiltration (CAVH). The results obtained suggest that this filter is a prototype of a new generation of hemofilters especially designed for CAVH. Its low resistance permits its use even in patients with severe hypotension. The high blood flows achieved at a given pressure reduce the risk of clotting and increase the ultrafiltration rate. When an average ultrafiltration of 20-25 ml/min is achieved in 24 hours CAVH becomes very efficient, and alternative techniques to increase its efficiency are no longer required.
    Keywords:
    Ultrafiltration (renal)
    This specification describes requirements and test methods for the qualification of Polyamide 11 (PA 11) bodied mechanical fittings for use with outside diameter controlled PA 11 pipe, and nominal 2 pipe size (IPS) and smaller. In addition, it specifies general requirements of the material from which these fittings are made. Performance requirements shall include tests to determine elevated temperature sustained pressure, tensile strength, in-line fitting, mechanical saddle fittings, temperature cycling, and joint constant tensile load.
    Citations (0)
    In order to research the performance of silver-coated polyamide filament,the physical mechanical properties and conductibility of silver-coated Polyamide filament were investigated.The results indicate that breaking strength of 140D/40f and 40D/12f silver-coated Polyamide filament is lower than that of polyamide.But breaking elongation is higher than that of polyamide.Resistance of silver-coated polyamide filament is higher than that of polyamide.Thus it greatly improves the antistatic property of product.The bonding power between silver plating layer and basal body is very strong.So the durability of silver-coated Polyamide filament is very well.
    Elongation
    Antistatic agent
    Citations (0)
    Ultrafiltration theory,the type of ultrafiltration membrane and the characteristics of ultrafiltration were briefly introduced in the paper.Then the application of ultrafiltration technology in the industry and the domestic wastewater was summarized emphatically.In the end,the development tendency of ultrafiltration also was forecasted.
    Ultrafiltration (renal)
    Membrane Technology
    Citations (0)
    Abstract Ten common dinitrophenyl amino acids were used to test the performance of polyamide layer chromatography for quantitative analysis. The polyamide layer is used as the stationary phase and U. V. photometric method is employed for quantitative estimation. The results show that high accuracy of quantitative analysis by polyamide layer can be achieved. Possibility of repeated use of polyamide layer was discussed also.
    Quantitative Analysis
    Citations (1)