[Incidence and distribution of glaucoma].
0
Citation
0
Reference
10
Related Paper
Cite
Charles L. Harris, MD, reviews safety and efficacy rates in a glaucoma case series after adding a proprietary laser system with probe to the surgical armamentarium.
Cite
Citations (0)
Suspect
Cite
Citations (0)
Cite
Citations (0)
Glaucoma valve
Refractory (planetary science)
Cite
Citations (0)
Cite
Citations (0)
To determine prevalence of glaucoma and glaucoma suspect in subjects 40 years and above in Sunsari district of eastern Nepal.A community based cross sectional study examining 1600 selected subjects was carried out. In all subjects best corrected visual acuity was determined. Oblique torch light test was used for anterior chamber depth evaluation. Intraocular pressure (IOP) measurements with Perkins tonometer and fundus examination were carried out in the community. Subjects diagnosed as glaucoma suspect were further evaluated in the hospital using slit lamp examination, gonioscopy and Goldmann perimetry. Glaucoma was defined by characteristic disc and visual field changes irrespective of the level of IOP.Of 1600 subjects examined, the prevalence of glaucoma was found to be 0.938%. The prevalences of primary open angle glaucoma, primary angle closure glaucoma, secondary glaucoma and ocular hypertension were 0.562%, 0.125%, 0.250% and 0.500% respectively. Lens induced glaucoma accounted for all the cases of secondary glaucoma.The prevalence of glaucoma in the Sunsari District of Nepal is 0.938%, which is lower than that reported in the neighboring regions. Lens induced glaucoma is highly prevalent as a cause of secondary glaucoma.
Gonioscopy
Optic disc
Fundus (uterus)
Cite
Citations (23)
Glaucoma surgery
Cite
Citations (5)
Cite
Citations (18)
To determine the discriminating ability of some parameters provided by Humphrey Matrix perimetry for early glaucoma detection.A prospective cross-sectional study was performed. Sixty-five primary open-angle glaucoma patients with early-stage visual field defects on standard automated perimetry (mean deviation = -1.98 +/- 1.93 dB) and 56 healthy subjects were included. All subjects performed the Humphrey Matrix perimetry with a threshold 30-2 strategy. The receiver operating characteristic (ROC) curve was constructed for each parameter and calculated the area under the ROC curve (AUC) to seek the best discriminating parameter for early glaucoma detection.The AUCs of Humphrey Matrix perimetry with the mean deviation, pattern standard deviation, Glaucoma Hemifield Test, number of points that have a p < 5% in pattern deviation plot (PDP) and number of points that have a p < 1% in PDP were 0.795, 0.808, 0.689, 0.985 and 0.946, respectively.Humphrey Matrix perimetry allowed accurate discrimination between normal and early glaucomatous eyes. The number of points that had a p < 5% in PDP was the best discriminating parameter for early glaucoma detection using Humphrey Matrix perimetry.
Absolute deviation
Cite
Citations (3)
Cite
Citations (0)