    Repair and Adjustment Methods for 4117-K1T Adjusting Valve in Synthesis Gas Turbine
    0
    Citation
    0
    Reference
    16
    Related Paper
    Abstract:
    The adjusting valve in synthesis gas turbine used in Ningxia Petrochemical Co.had never been disassembled and overhauled before 2003,thus,there was no operative rules for repair and adjustment.In 2003,the synthesis ammonia plant was shutdown and repaired completely,this adjusting valve was also overhauled.With the experience in recent years,in this article,the methods of repair and adjustment for this adjusting valve were simply described and summarized.
    Keywords:
    Petrochemical
    Shut down
    Ammonia production
    Introduce the trouble cause and surfacing technology plan of Zhanjiang power plant 300MW turbine high-pressure adjusting valve, analyze the technical problems which appear during the procession of welding and the technology measures which should be taken.
    Citations (0)
    Summarizes and analyzes the problems appearing in the course of adjusting for A649H-P4539C pulsing safety valve of intermediate pressure boiler in Shizuishan Power Plant, puts forward measures and suggestions for dealing with the common problems of safety valve adjusting.
    Safety valve
    Citations (0)
    Based on experience obtained in tackling troubles encountered by 300 MW,600 MW pure DEH controlled units of Dongfang Steam Turbine Co.Ltd.during installation and operation periods,normal troubles occurring in the high-pressure main stop valve and high-pressure control valve are classified as follows: seizing up and abnormal noise in operation of high-pressure control valve;steam leakage in bonnet and valve rod of main stop valve.The effective way to solve this problem is to secure enough gap between valve rod and pocket,suitable gap between valve disc and pocket,obey installation sequence strictly,guarantee sound sealing of all sealing surfaces.
    Relief valve
    Control valves
    Leakage (economics)
    Flow control valve
    Safety valve
    Valve actuator
    Citations (0)
    Damages of gas valve often appear,no matter an inlet valve or an exhaust one,because of some bad working conditions.In this paper,the different damage styles and repair methods are introduced.The daily maintenance and management,to which we should pay attention,are also put forward.
    Valve timing
    Valve seat
    Check valve
    Gas engine
    Citations (0)
    The cause for the damage to the pre-start valve seat of CB25-91/10/1.2steam turbine regulator valve was identified by doing metallographic analysis,and necessary improvements in design and maintenance are suggested as appropriate.
    Safety valve
    Valve seat
    Pressure regulator
    Control valves
    Citations (0)
    In this paper, Tongliao power plant 4 sets of 200 MW unit high pressure main stop valve pre opening and cause valve jam has carried on the detailed analysis, and put forward specific improvement measures, to ensure crew safety, stable operation, reliable basis is provided.
    Safety valve
    Valve seat
    Root Cause Analysis
    Citations (0)
    In one large synthetic ammonia construction,there is a high pressure steam turbine which is used as a drive for synthetic gas compressor.When the compressor startup again,there were faults occurred for three times in adjusting valve which seriously affect the normal operation of whole synthetic ammonia construction and a great amount of economic loss created.By analyzing the faults occurred in the adjusting valve,the cause of these faults was found.The correcting measures to remove the fault in adjusting valve,then,proposed.These measures can be referenced in diagnosing and removing such faults.
    Safety valve
    Citations (0)
    The paper describes the necessity of new valves’pre-maintain before operation,introduces preliminary preparation and maintenance steps for the new valves before operation.Valve maintenance is divided into three parts,that is,(1)valve maintenance before installation and welding;(2)inspection and maintenance during pressure testing and(3)maintenance and repair forproblemvalve before putting into operation. Requirements for valve installation and welding are presented.
    Citations (0)
    The electro-hydraulic control system of N3.782-0.8538 variable-speed steam turbine consists of two relatively independent and interdependent parts,which are governing valve high-pressure fire-resistant oil and throttle valve low-pressure lube oil control systems.During commissioning and start-up operation period in a power plant,governing valve sloshing,latch-on failure,throttle valve opening abnormally and high pressure of regulating oil occurred frequently.By comprehensive analysis and study on the working principle of control system oil circuit,internal structure of important parts,and dismantling checking the throttle starting valve,manual shutdown valve and so on,it was found that control system connection loosening will lead to governing valve sloshing;the seizure and oil drain of throttle starting valve and manual shutdown valve will lead to steam turbine latch-on failure,throttle valve opening failure,regulating oil pressure relative high and so on.
    Throttle
    Hydraulic fluid
    Control valves
    Relief valve
    Shut down
    Safety valve
    Valve timing
    Pressure Control
    Valve actuator
    Oil pump
    Citations (1)
    Turbine valve discharge characteristic was tested to resolve the problem of high heat-consumption in one 600MW power plant and the result indicated that pressure loss between front and back main steam valve groups was too large.Loose valve seat of adjusting valve,too small flow area between valve seat and valve head,poor aerodynamic performance of main steam valve groups were main factors responsible for large damper loss.In the end,relevant solutions and modify project were given.
    Valve seat
    Safety valve
    Citations (0)