Direct transaortic transcather valve-in-valve implantation into a mechanical aortic valve prosthesis during left ventricular assist device implantation: description of a surgical technique.

2021 
The presence of a mechanical aortic valve prosthesis is considered a relative contraindication for left ventricular assist device implantation (LVAD) due to the occurrence of thromboembolic events. Five patients were operated on for LVAD implantation with status post mechanical aortic valve implantation (n = 3 with status post Bentall procedure). After removal of the leaflets, a transcatheter balloon-expandable valve was placed within the mechanical ring in all patients. Three patients were discharged from hospital with a maximum follow-up of 3.3 years. Transaortic transcatheter valve implantation into a mechanical aortic valve during LVAD implantation is a feasible option. It reduces operative times and might also prevent thromboembolic events.