The distribution of the temperature field of the green electrodes formed by extrusion from Sinosteel Jilin Carbon Co.,Ltd., was discussed, and the test results were analysed. The temperature field of the green electrodes classified as uniform distribution and non-uniform distribution is determined. The analysed results show that the different temperature field distribution has different effects on the structure of the green electrode. The reasons caused the structural defect of the green electrode can be found through the testing for the temperature field distribution, which would provide an reference for the production of the green electrodes formed by extrusion.