Inhalation airflow and ventilation efficiency in subject-specific human upper airways.
2020
Abstract The present study numerically investigated the transportation time of the inhaled chemicals in three realistic human airway models by adopting a methodology from the field of the building ventilation. Two indexes including “scale of ventilation efficiency 3 (SVE3)” and “local purging flow rate (L-PFR)” were used to evaluate the respective arrival time and staying time under different inhalation flow rates. The general trend of the SVE3 was predicted as expected and the exceptions of the nasal cavities were attributed to the uneven allocation of the inhaled flow between the internal channels and the formation of the vortex circulation there. The complicated situation of the L-PFR was also explained by the structure constrains. Moreover, the variation of the two indexes with the flow rate was sensitive to the inter-subjective differences but the distribution pattern was not changed significantly. By combining the SVE3 and L-PFR, it could help with assessing the potential effect of the inhaled chemicals on the human health for engineering applications to which the relative impacts are more interested than the absolute value. But for the precise evaluation regarding a specific chemical, comprehensive simulation is still necessary with the surface adsorption included under realistic respiration cycles.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
46
References
2
Citations
NaN
KQI