Accessibility evaluation of the IFMIF liquid lithium loop considering activated erosion/corrosion materials deposition

2005 
Abstract This paper presents an evaluation of accessibility of the Li loop piping considering activated corrosion product. International Fusion Materials Irradiation Facility (IFMIF) is a deuteron-lithium (Li) stripping reaction neutron source for fusion materials testing. Target assembly and back wall are designed as fully remote maintenance component. Accessibility around the Li loop piping will depend on activation level of the deposition materials due to the back wall erosion/corrosion process under liquid Li flow. Activation level of the corrosion products coming from the AISI 316LN back wall is calculated by the ACT-4 of the THIDA-2 code system. The total activities after 1 day, 1 week, 1 month and 1 year cooling are 3.1 × 10 14 , 2.8 × 10 14 , 2.3 × 10 14 and 7.5 × 10 13  Bq/kg, respectively. Radiation dose rate around the Li loop pipe is calculated by QAD-CGGP2R code. Activated area of the back wall is 100 cm 2 . Corrosion rate is assumed 1 μm/year. When 10% of the corrosion material is supposed to be deposited on the inner surface of the pipe, the dose rate is calculated to be less than a permissible level of 10 μSv/h for hands-on maintenance, therefore, the maintenance work is assessed to be possible.