Hydrogen and Hydrazine Co-injection to Mitigate Stress Corrosion Cracking of Structural Materials in Boiling Water Reactors, (VI) The Effect of Ammonia on Intergranular Stress Corrosion Cracking

2007 
Hydrogen and hydrazine co-injection into a boiling water reactor was considered as a new mitigation method of stress corrosion cracking (SCC). In this method, some amount of ammonia will be formed by the decomposition of hydrazine. The effect of ammonia on SCC susceptibility was studied over a wide range of electrochemical corrosion potentials (ECPs) in 288_C water by conducting slow strain rate technique SCC experiments (SSRTs). ECP was changed from _0:6V versus the standard hydrogen electrode (V(SHE)) to 0.1 V(SHE) by controlling dissolved oxygen concentration. Ammonia concentration was controlled to have values of 100 and 530 ppb. Similarly, sulfuric acid was injected to confirm the difference in the effect of injected chemical compounds on SCC susceptibility. The intergranular stress corrosion cracking (IGSCC) fraction, which was used as the index of SCC susceptibility, decreased with decreasing ECP for the case of no chemical injection. Sulfuric acid enhanced the IGSCC fraction. These data were in go...