Monte Carlo simulation of various source-product geometries for a proposed multi-product gamma irradiator facility.
2009
Radiation processing plants are designed to deliver a prescribed dose to product materials within the acceptable uniformity to meet the national standards. The dose uniformity ratios for four different product geometries of a proposed 37 PBq (10 6 Ci) 60 Co-based, multi-product irradiator facility in India are evaluated using the Monte Carlo method for various product densities, 0.15 g cm -3 , 0.4 g cm -3 , and 0.6 g cm -3 . The calculations are also carried out using the point kernel method for comparison purposes. The agreement between Monte Carlo and point kernel methods is within 3 to 15%. The suitable product geometry is identified based on dose uniformity ratios.