Evaluation of a lateral flow–based technology card for blood typing using a simplified protocol in a model of extreme blood sampling conditions

2018 
BACKGROUND: Life-threatening situations requiring blood transfusion under extreme conditions or in remote and austere locations, such as the battlefield or in traffic accidents, would benefit from reliable blood typing practices that are easily understood by a nonscientist or nonlaboratory technician and provide quick results. STUDY DESIGN AND METHODS: A simplified protocol was developed for the lateral flow-based device MDmulticard ABO-D-Rh subgroups-K. Its performance was compared to a reference method (PK7300, Beckman Coulter) in native blood samples from donors. The method was tested on blood samples stressed in vitro as a model of hemorrhage cases (through hemodilution using physiologic serum) and dehydration (through hemoconcentration by removing an aliquot of plasma after centrifugation), respectively. RESULTS: A total of 146 tests were performed on 52 samples; 126 in the hemodilution group (42 for each native, diluted 1/2, and diluted 1/4 samples) and 20 in the hemoconcentration group (10 for each native and 10% concentrated samples). Hematocrit in the tested samples ranged from 9.8% to 57.6% while hemoglobin levels ranged from 3.2 to 20.1 g/dL. The phenotype profile detected with the MDmulticard using the simplified protocol resulted in 22 A, seven B, 20 O, and three AB, of which nine were D- and five were Kell positive. No discrepancies were found with respect to the results obtained with the reference method. CONCLUSION: The simplified protocol for MDmulticard use could be considered a reliable method for blood typing in extreme environment or emergency situations, worsened by red blood cell dilution or concentration.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    11
    References
    1
    Citations
    NaN
    KQI
    []