Application of the R2Smesh approach for the accurate estimation of photon radiation dose fields around activated ITER in-vessel components

2015 
Abstract The R2Smesh (“Rigorous 2-step”) approach, developed by KIT for the determination of shut down dose rate distributions on high resolution mesh grids, can be utilized to calculate photon radiation dose fields around activated components which are moved from the irradiation site in ITER to some external location. In this work, the R2Smesh approach has been applied to dose rate analyses of various ITER in-vessel components of high complexity: A divertor cassette, four first wall modules, a generic diagnostic equatorial port plug and two test blanket modules. The considered components were first irradiated in ITER, and then moved to the transfer cask together with the associated decay gamma source distribution for the calculation of high resolution radiation dose fields in and around the transfer cask. The R2Smesh approach was shown to be a versatile tool for performing such analyses.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    16
    References
    1
    Citations
    NaN
    KQI
    []