Detection of embedded fatigue cracks in Inconel weld overlay and the evaluation of the minimum thickness of the weld overlay using eddy current testing

2006 
Abstract This study evaluates the applicability of eddy current testing to the detection and sizing of fatigue cracks embedded in Inconel weld overlays. Welded plate specimens, which model head penetration welds and their weld overlays, are fabricated, and fatigue cracks are artificially introduced into the specimens. Eddy current inspections are performed using a uniform eddy current probe driven with 10 kHz, and all of the fatigue cracks are detected with clear signals. Subsequent numerical inversions estimate that the minimum thicknesses of the weld overlays are 1.47, 2.17, and 2.23 mm, whereas true thicknesses revealed through destructive testing are 1.51, 3.25, and 2.10 mm, respectively. Thicknesses are also evaluated using potential drop and ultrasonic testing methods; the results demonstrate that eddy current testing is the most efficient of the three methods.