Modeling of Ash Deposition in the Convective Pass of a Coal-Fired Boiler
1996
The Energy & Environmental Research Center (EERC) has developed a personal computer (PC)-based model, FOULER, to predict convective pass fouling deposit formation in coal-fired boilers. This program is used to evaluate the effects of coal quality and operational changes on both high-and low-temperature fouling. In addition, the effects of coal cleaning, blending, and switching options can be evaluated. FOULER will be incorporated in the Coal Quality Expert (CQE) software project. CQE is a comprehensive, PC-based program that can be used to evaluate various potential coal cleaning, blending, and switching options to reduce power plant emissions while minimizing generation costs.
Keywords:
- Correction
- Source
- Cite