Industrial Flare Performance at Low Flow Conditions. 1. Study Overview

2012 
A series of full-scale industrial flare tests were conducted at low flow and low BTU content of flared gases at an industrial test facility. Both a 24” diameter air-assisted flare with a flow capacity of 144,000 lb/h and a 36” steam-assisted flare with a flow capacity of 937,000 lb/h were employed in the testing. Flared gases were mixtures of natural gas, propylene, and nitrogen or natural gas, propane, and nitrogen. Natural gas to propane or propylene ratio was 1:4 by volume for all experiments. Nitrogen was used as a diluent to achieve the desired lower heating values (LHV) for the vent gas. The range of flared gas flow rates was 0.1% to 0.65% of the flare’s design capacity. Flare operation was characterized by measurements of flow rates to the flare, extractive measurements made of the vent gases fed to the flare, extractive measurements made at the end of the flare plume, and remote sensing measurements of the flare plume made by a variety of spectroscopic instruments. Destruction/removal efficiencies...