Point-of-care measured platelet inhibition correlates with a reduced risk of an adverse cardiac event after percutaneous coronary intervention: results of the GOLD (AU-Assessing Ultegra) multicenter study☆

2001 
Background—The optimal level of platelet inhibition with a glycoprotein (GP) IIb/IIIa antagonist necessary to minimize thrombotic complications in patients undergoing a percutaneous coronary intervention (PCI) is currently unknown. Methods and Results—Five hundred patients undergoing a PCI with the planned use of a GP IIb/IIIa inhibitor had platelet inhibition measured at 10 minutes, 1 hour, 8 hours, and 24 hours after the initiation of therapy with the Ultegra Rapid Platelet Function Assay (Accumetrics). Major adverse cardiac events (MACEs: composite of death, myocardial infarction, and urgent target vessel revascularization) were prospectively monitored, and the incidence correlated with the measured level of platelet function inhibition at all time points. One quarter of all patients did not achieve ≥95% inhibition 10 minutes after the bolus and experienced a significantly higher incidence of MACEs (14.4% versus 6.4%, P=0.006). Patients whose platelet function was <70% inhibited at 8 hours after the st...