Anterior cervical fusion: a biomechanical comparison of 4 techniques. Laboratory investigation.

2008 
Object Cervical instrumented fusion is currently performed using several fixation methods. In the present paper, the authors compare the following 4 implantation methods: a stand-alone cage, a cage supplemented by an anterior locking plate, a cage supplemented by an anterior dynamic plate, and a dynamic combined plate–cage device. Methods Four finite element models of the C4–7 segments were built, each including a different instrumented fixation type at the C5–6 level. A compressive preload of 100 N combined with a pure moment of 2.5 Nm in flexion, extension, right lateral bending, and right axial rotation was applied to the 4 models. The segmental principal ranges of motion and the load shared by the interbody cage were obtained for each simulation. Results The stand-alone cage showed the lowest stabilization capability among the 4 configurations investigated, but it was still significant. The cage supplemented by the locking plate was very stiff in all directions. The 2 dynamic plate configurations redu...