Effect of post-weld heat treatment on the mechanical properties of CLAM/316L dissimilar joint

2015 
Abstract Dissimilar welding between China low activation martensitic (CLAM) steel and 316L austenitic stainless steel was investigated to achieve the reliable connection between test blanket modules (TBMs) and piping system in the international thermonuclear experimental reactor (ITER). The dissimilar joints were welded by tungsten inert gas (TIG) welding process with a filler material type-309. In order to stabilize the microstructure and improve the strength and toughness, post-weld heat treatments (PWHTs) of tempering at 740 °C, 780 °C and 820 °C, respectively, for 2 h were performed. The microstructure observation showed that tempering at 740 °C for 2 h was the preferable PWHT rule in this work. After the treatment, the hardening in heat affected zone (HAZ) on the CLAM steel side decreased remarkably. The tensile strength of the joint was roughly the same as that of the base metal. The impact toughness of HAZ on the CLAM steel side was 77% of that of the base metal. The absorbed energy of HAZ of 316L steel decreased by 93 J, and that of weld metal (WM) was 110 J after the treatment.