Influencing Factors on the Accuracy of Soil Calibration Models by EDG

2021 
Compaction is an important standard in evaluating the quality of earth filling work. The EDG, an electrical density gauge, is a new type of fast and nondestructive compaction detection equipment. It is used to test the dry density and water content of the soil by establishing a soil calibration model while the accuracy of measurement is mainly based on the precision of equation of calibration model. In this paper, the factors affecting the accuracy of the soil calibration model were studied by an indoor calibration test, and soil samples were prepared to verify the accuracy of the soil calibration model. The test results showed that the dry density range, water content range, and sample quantity 13 samples of soil had a significant influence on the correlation coefficient (R2) of the equation of the soil calibration model. In addition, when using the calibration model with different sample numbers and sample combinations but similar correlation coefficients to test multiple groups of density and moisture content, there are also differences in the expected value and standard deviation of the error probability curve of the test results. In the engineering practice, the reasonable sample quantity was determined by the applicable range of dry density and water content obtained from the measurement error analysis of the soil calibration model.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []