The application of an external electric field is known to improve flame stability significantly. Until now, few studies have proposed modelling approaches for combustion in the presence of an externally applied voltage. In these numerical studies, the negative ions are overlooked, and only the displacement of positive ions and electrons under the effect of a direct electric field was examined. In the present paper, a simplified mathematical model including negative ions is proposed based on a kinetic mechanism featuring 39 ionic reactions and 5 charged species. This mechanism is first evaluated by comparison of a monodimensional premixed flame with the available experimental data. Then it is used to analyse the stabilisation mechanism of a diffusion lifted flame in the presence of direct or alternating electric fields. It was concluded that the role of negative ions is crucial, and they are not to be neglected. Moreover, the simulations have shown that the magnitude of the flame stabilisation improvement ...