A Parameter Determination Method of Distribution Voltage Regulators Considering Tap Change and Voltage Profile

2012 
This paper proposes a parameter determination method of distribution voltage regulators load ratio control transformers (LRT) and step voltage regulators (SVR) considering the tap change and voltage profile. The method takes two procedures in order to simplify the optimization problem and to reduce calculation time. One is to simultaneously determine the control parameters of LRT and SVR minimizing voltage violations and voltage variations. The algorithm is based on particle swarm optimization (PSO), which is one of non-linear optimization methods by using a concept of swarm intelligence. Another is to determine the dead-band width of LRT and SVR on the basis of bi-evaluation of tap change and voltage margin. The concept of a Pareto optimal solution is used for the decision of the best dead-band width. As the results of numerical simulations using distribution network model, the validity of the proposed method has been affirmed.
    • Correction