Ultrasound Elastography as a Non-Invasive Method to Monitor Liver Disease in Children with Short Bowel Syndrome: Updated Results

2019 
Abstract Purpose The purpose of the study was to determine the accuracy of acoustic radiation force impulse (ARFI) ultrasound elastography in assessing the degree of liver disease in children with short bowel syndrome (SBS). Methods A prospective observational cohort study of patients with SBS who underwent a liver biopsy and ARFI elastography was performed. Mean shear wave speed (SWS) and stage of fibrosis was evaluated using t-tests. Receiver operating characteristic curves (ROC) were generated and the area under the curves (AUC) estimated in order to assess the accuracy of SWS measurements to discriminate between stages of fibrosis. Results Thirty-seven paired elastography and biopsy samples from 31 patients were included. The median age was 0.6 years, and 61% were male. There was a significant positive correlation between stage of fibrosis and mean SWS (β = 0.16 m/s increase per stage, p = Conclusion ARFI elastography is an accurate, non-invasive method to monitor liver disease in children with SBS. Type of Study Retrospective Cohort Study Level of Evidence II