Three example applications of optimization techniques to Department of Energy contractor radiation protection programs

1989 
Six numerical examples of optimization of radiation protection are provided in the appendices of ICRP Publication 37. In each case, the calculations are based on fairly well defined parameters and assumptions that were well understood. In this paper, we have examined two numerical examples that are based on empirical data and less certain assumptions. These examples may represent typical applications of optimization principles to the evaluation of specific elements of a radiation protection program. In the first example, the optimum bioassay frequency for tritium workers was found to be once every 95 days, which compared well with ICRP Publication 10 recommendations. However, this result depended heavily on the assumption that the value of a potential undetected rem was US $1000. The second example showed that the optimum frequency for recalibrating Cutie Pie (CP) type ionization chamber survey instruments was once every 102 days, which compared well with the Hanford standard frequency of once every 90 days. This result depended largely on the assumption that an improperly operating CP instrument could lead to a serious overexposure. These examples have led us to conclude that optimization of radiation protection programs must be a very dynamic process. Examples must be recalculated as empiricalmore » data expand and improve and as the uncertainties surrounding assumptions are reduced.« less