Flash-over 이후의 바닥패턴 해석에 관한 연구

2020 
Determination of the correct point of ignition is important in the investigation. It depends on the interpretation of the situation and the fire pattern, and it is similar to the flow pattern in the flooring due to the radiation of the high temperature after the flashover. There are many difficulties in determining the ignition of the pattern, and the confusion are increased. There are bottom after Flashover, even on NFPA921 like the pour pattern of the method. It is said that the splatter of the oil pattern should not be confused with the use of actual cotton swab. Previous works on the bottom combustion pattern and the oil fire pattern after Flashover are analysed, and floating combustion pattern and the oil fire pattern are suggested.