Dead beat control of three phase PWM inverter
1990
A novel method for microprocessor control of three-phase sinusoidal-voltage pulse-width-modulated (PWM) inverters is proposed. First, the discretized state equations of the inverter main circuit on the d-q frame are derived. An algorithm for dead beat control with a current minor loop that constrains the inverter current within the safety limit is subsequently developed. To compensate the computing time delay, a second-order prediction method and a novel discretization method using twice the time of the sampling period have been adopted. This method is especially suitable for inverters using high-speed switching devices and digital signal processors. The validity of the control system has been demonstrated by precise simulation using a hybrid computer. >