PERBANDINGAN UNJUK KERJA POLY ZIRCONIUM COMPOUND (PZC) DARI KAKEN DENGAN POLIMER BERBASIS ZIRKONIUM (PBZ) DARI PTRR UNTUK KOLOM GENERATOR 99Mo/99mTc

2016 
ABSTRAK PERBANDINGAN UNJUK KERJA POLY ZIRCONIUM COMPOUND (PZC) DARI KAKEN DENGAN POLIMER BERBASIS ZIRKONIUM (PBZ) DARI PTRR UNTUK KOLOM GENERATOR 99 Mo/ 99m Tc. Generator 99 Mo/ 99m Tc menghasilkan radioisotop 99m Tc yang merupakan radioisotop medis utama yang digunakan untuk diagnosis di bidang kedokteran nuklir. Lima (5) buah reaktor nuklir di dunia penghasil utama radioisotop 99 Mo (radioisotop induk 99m Tc) dari fisi uranium mengalami gangguan serius, demikian juga produksi radioisotop medis 99m Tc. Karena itu proses produksi radioisotop induk 99 Mo menggunakan metode aktivasi neutron dari target molibdenum dilakukan. Radioisotop 99 Mo hasil aktivasi neutron ini mempunyai radioaktivitas jenis rendah, sehingga tidak cocok menggunakan kolom alumina yang kapasitas serapnya terhadap molibdenum kecil (± 2 mg Mo/g Al). Sebagai alternatif digunakan senyawa polimer zirconium yang mempunyai kapasitas serap tinggi (270 mg/g). Penelitian ini membahas perbandingan unjuk kerja Poly Zirconium Compound (PZC) yang dihasilkan oleh Kaken, Co. Jepang dan matrik Polimer Berbasis Zirkonium (PBZ) hasil sintesis PTRR, BATAN. Penelitian ini menetapkan kapasitas serap, efisiensi penyerapan, pengotor 99 Mo, efisiensi pemisahan 99m Tc dan profil elusi. Hasil unjuk kerja PZC untuk parameter parameter tersebut di atas masing masing 210,62 mg/g, 77,4%, 0,0187 mCi/mCi dan 0,0132 mCi/mCi, 276,35 mCi (86,15%). Sedangkan untuk PBZ masing masing 188,81 mg/g, 79,33%, 0,2337 mCi/mCi dan 31,5615 mCi/mCi, 43,39 mCi (67,90%). Profil elusi 99m Tc dari PZC dan PBZ hampir mirip, bahwa tingkat radioaktivitas 99m Tc di peroleh sebelum volume eluen mencapai     10 mL. Kata kunci: Polimer zirconium, 99 Mo. 99m Tc, kolom generator ABSTRACT PERFORMANCE COMPARISON OF POLY ZIRCONIUM COMPOUND ( PZC ) KAKEN WITH POLYMER BASED ZIRCONIUM ( PBZ ) FROM PTRR FOR 99 MO/ 99M TC GENERATOR COLUMN. 99 Mo/ 99m Tc generator produce radioisotopes 99m Tc which is a major medical on the world radioisotopes are used for diagnosis in the field of nuclear medicine. Five (5) of a nuclear reactor in the world producing radioisotopes 99 Mo main (parent of 99m Tc radioisotope) from uranium fission seriously impaired, as well as the production of medical radioisotopes 99m Tc. Because the parent radioisotope 99 Mo production process using neutron activation method from molybdenum targets do. Radioisotope 99 Mo from neutron activation results this has kind of low radioactivity, so it is not appropriate to use the alumina column, because the absortion capacity of molybdenum small (Mo ± 2 mg /g Al). As an alternative use of zirconium polymer compound having a high absorption capacity (270 mg/g). This study discusses the performance comparison Poly Zirconium Compound (PZC) by Kaken Co. Japan and Polymer Based Zirconium (PBZ) synthesized by PTRR, BATAN. This study establishes absorption capacity, absorption efficiency, impurity 99 Mo , separation efficiency of 99m Tc and of the elution profile. Results study, PZC performance parameters for the aforementioned 210.62 mg/g, 77.4%, 0.0187 m Ci/mCi and 0.0132 m Ci/mCi, 276.35 mCi (86.15%), respectively. As for PBZ, 188.81 mg/g, 79.33%, 0.2337 m Ci/mCi and 31.5615 m Ci/mCi, 43.39 mCi (67.90%). 99mTc elution profile of the PZC and PBZ almost similar, that 99m Tc radioactivity levels obtained before the eluent volume reached 10 mL. Keywords : polymer zirconium , 99 Mo, 99m Tc , generator column.
    • Correction
    • Source
    • Cite
    • Save
    • Machine Reading By IdeaReader
    0
    References
    0
    Citations
    NaN
    KQI
    []