The DNAA system made up of pneumatic transport system, neutron detector assembly, and signal processing equipment was installed in the High-flux Advanced Neutron Application Reactor (HANARO). The optimized position of the detector in the delayed neutron counting (DNC) system was evaluated at a distance 15.1 cm from center of the DNC system with 18 He-3 detectors using MCNP simulation. The system shows excellent linearity from 0.67 ng to 713 ng U-235, and reproducibility of 1.26% standard deviation for the various mass groups of U-235 samples. The DNAA system shows detection efficiency of ~30 % and U-235 detection limit of 1ng. This system can be used on a screening method to assist the environmental sample analysis and to protect the clean room from elevated levels of fissile material that might be in routine samples.