Intra and inter‐day repeatability of peripheral arterial function: suitability and potential limitations
2016
The present study aimed to investigate the inter- and intraday repeatability of reactive hyperemia index (RHI) measured by Endo-PAT in healthy volunteers.
Interday RHI repeatability was tested in two consecutive days in a group of thirty-one male subjects. Intraday repeatability was investigated at baseline and after 2 and 4 h in a group of sixteen volunteers. Data were evaluated by analysis of variance. Bland–Altman plot, coefficient of variation (CV), coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were measured.
While interday RHI repeatability was found to be reliable (CV: 6.0%; CR: 0.51; ICC: 0.77), multiple evaluations within the same day significantly (p<0.001) affected RHI (repeatability of the measurement - CV: 18.8%; CR: 1.26; ICC: 0.48). In particular, a significant increase in RHI occurred at 4 h compared to 2 h (+16.8%; p<0.05) and to baseline (+30.1%; p<0.05).
In conclusion, RHI showed good interday but poor intraday repeatability. Multiple evaluations increased RHI especially in subjects with endothelial dysfunction who improved or reversed their impairment. These results show the potential limitations of multiple Endo-PAT measurements within the same day and the importance of standardizing the protocols before RHI evaluations.
This article is protected by copyright. All rights reserved.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
42
References
2
Citations
NaN
KQI