The Small Membrane Filter Method of Microscopy to Diagnose Pulmonary Tuberculosis

2012 
ABSTRACT We modified microscopy for acid-fast bacilli to diagnose tuberculosis (TB) using small membrane filters (SMFs) after special processing and prefiltration. With the first specimen obtained from each of 335 persons suspected of having TB, the sensitivity of the new SMF method using fluorescence microscopy (FM) was 89% (95% confidence interval [CI]: 80%, 95%). This was significantly better ( P = 0.0001) than the sensitivity of routine FM of centrifuged specimens of 60% (95% CI: 49%, 71%) or that of direct sputum smears of 56% (95% CI: 40%, 72%).