Can a digital slide scanner and viewing technique assist the visual scoring for the cytokinesis-block micronucleus cytome assay?

2020 
: The cytokinesis-block micronucleus cytome (CBMNcyt) assay is a comprehensive method to measure DNA damage, cytostasis and cytotoxicity caused by nutritional, radiation and chemical factors. A slide imaging technique has been identified as a new method to assist with the visual scoring of cells for the CBMNcyt assay. A NanoZoomer S60 Digital Pathology slide scanner was used to view WIL2-NS cells treated with hydrogen peroxide (H2O2) and measure CBMNcyt assay biomarkers using a high-definition desktop computer screen. The H2O2-treated WIL2-NS cells were also scored visually using a standard light microscope, and the two visual scoring methods were compared. Good agreement was found between the scoring methods for all DNA damage indices (micronuclei, nucleoplasmic bridges and nuclear buds) and nuclear division index with correlation R values ranging from 0.438 to 0.789, P < 0.05. Apoptotic and necrotic cell frequency was lower for the NanoZoomer scoring method, but necrotic frequency correlated well with the direct visual microscope method (R = 0.703, P < 0.0001). Considerable advantages of the NanoZoomer scoring method compared to direct visual microscopy includes reduced scoring time, improved ergonomics and a reduction in scorer fatigue. This study indicates that a digital slide scanning and viewing technique may assist with visual scoring for the CBMNcyt assay and provides similar results to conventional direct visual scoring.