Experimental study on characteristics of sodium fire in a columnar flow with discontinuous injections

2018 
ABSTRACTIn the operation of the sodium-cooled fast reactor, the accident caused by the leakage and combustion of liquid sodium is common and frequent in sodium-related facilities. In this paper, an experiment Harbin Engineering University-Sodium Columnar Fire 4 (HEU-SCF4) is carried out to focus on the combustion characteristics in a discontinuous columnar flow. Liquid sodium (250°C) with the flux of about 1.0 m3/h was injected into a 7.9 m3 stainless steel cylindrical test chamber twice to shape the sodium fire in a columnar flow with discontinuous injections. The temperature, pressure data, and heat release rate in the test chamber were acquired and analyzed. It is found that each injection would cause a peak of space temperature, and it takes much shorter time to reach temperature peak in the second injection than the first injection. The peaks of pressure and heat release rate caused by the second injection are much higher than those caused by the first injection. This study is promising to evaluate t...