Effect of Surface Roughness Location and Reynolds Number on Compressor Cascade Performance

2010 
An experimental work has been conducted in a linear compressor cascade to find out the effect of surface roughness and Reynolds number. Surveys were conducted with different roughness size and Reynolds number. The k s /c value of each roughness is 0.0006, 0.0090, 0.00150, 0.00213, and 0.00425. The range of Reynolds number is 300,000~600,000 and conducted with roughened blade, which roughness Ra is 2.89 microns. Flow pressure, velocity, and angle have been found out via 5 hole probe. Pressure loss and deviation increased with increasing roughness. In the low Reynolds number under 500,000, tested roughness does not affect to the performance of compressor cascade. However, roughness is very sensitive to pressure loss in high Reynolds number over 550,000.