VNUS Closure® FAST Radiofrequency of the Great Saphenous Vein for Superficial Venous Insufficiency: Experience of the CH of Cholet in France

2021 
Background:The objective of this work was to evaluate the first results of the radio ablation of the great saphenous vein in the processing of chronic venous insufficiency. Method: This is a monocentric retrospective study of radio ablation of the great saphenous vein using VNUS Closure® FAST for superficial venous insufficiency of the great saphenous vein, between January 2012 and December 2014. Results: 42 patients (57 limbs) were operated on with this technology. There were 33 women and 9 men (mean age: 46.5 years). Thirty-nine patients (92. 8%) were symptomatic. Thirty-two patients (76.1%) were classified CEAP 2. The average diameter of the saphenous vein was 8.5 ± 1.5 mm. Three patients (7.1%) had a percutaneous approach. A perfect occlusion of the saphenous vein was observed in all patients. No incident or undesirable event was observed during the procedure. One case of delayed deep-vein thrombosis was observed. At one month of follow-up, six patients (14.2%) had induration opposite to the occluded vein. Forty-three percent of the patients stated they were very satisfied with the procedure. Conclusion: The effectiveness, security and simplicity of the closure method are real. More studies are necessary to assess the long-term results of this procedure.