Postoperative Complications in Breast Reconstruction With Porcine Acellular Dermis and Polypropylene Meshes in Subpectoral Implant Placement.

2021 
Aim This research compares postoperative complication rates with Strattice™, SERAGYN® BR, and TiLOOP® Bra interposition devices for subpectoral implant placement after skin or nipple sparing mastectomy. Patients and methods 188 breast reconstructions in 157 patients after primary (n=96), secondary (n=71), or prophylactic (n=21) surgery were analyzed regarding major and minor complications. Results With acellular dermal matrix (ADM) Strattice™, 27.5% major and 27.5% minor complications occurred. Implant loss rates were 27.3% in primary and 30.8% in secondary reconstructions. With SERAGYN® BR, 11.1% major and 13,0% minor complications occurred. Implant losses (6.1%) occurred exclusively in primary reconstructions. With TiLOOP® Bra, 14.9% major and 9.6% minor complications occurred. Implant loss rates were 7.7% in primary and 7.1% in secondary reconstructions. Conclusion ADM was associated with high complication rates in primary and secondary reconstructions. Low complication rates were seen with mesh interposition devices in primary, secondary, and prophylactic reconstructions.