Solvent Hold Tank Sample Results for MCU-15-389-390 and MCU-15-439-440-441. February 2015 Monthly Samples

2015 
Savannah River National Laboratory (SRNL) received two sets of Solvent Hold Tank (SHT) samples (MCU-15-389 and MCU-15-390 pulled on February 23, 2015 and MCU-15-439, MCU-15-440, and MCU-15-441 pulled on February 28, 2015) for analysis. The samples in each set were combined and analyzed for composition. Analysis of the composite samples MCU-15-389-390 and MCU-15-439-440- 441 indicated a low concentration (~ 92 to 93 % of nominal) of the suppressor (TiDG) and slightly below nominal concentrations of the extractant (MaxCalix), but nominal levels of the modifier (CS-7SB) and of the Isopar™ L. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on February 22, 2015. Despite that the values are below the target component levels, the current levels of TiDG and MaxCalix are sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent. However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.