An Example Evaluation of IGCC Performance Test Code ASME PTC47

2002 
Integrated Gasification Combined Cycle (IGCC) utilizing solid and unconventional liquid fuels has now reached commercial stage as evidenced by their world wide construction and successful operation. The proposed ASME Performance Test Code 47 (PTC47) provides the users and owners of these new power plants, the guidance and procedures on conducting a performance test and evaluate the deviation from the performance guarantees. This paper reports the use of PTC47 codes in evaluating the test correction factors for the Wabash River IGCC Power Plant.Copyright © 2002 by ASME