Magneto-Rayleigh-Taylor experiments on a MegaAmpere linear transformer driver

2012 
Experiments have been performed on a nominal 100 ns rise time, MegaAmpere (MA)-class linear transformer driver to explore the magneto-Rayleigh-Taylor (MRT) instability in planar geometry. Plasma loads consisted of ablated 400 nm-thick, 1 cm-wide aluminum foils located between two parallel-plate return-current electrodes. Plasma acceleration was adjusted by offsetting the position of the foil (cathode) between the anode plates. Diagnostics included double-pulse, sub-ns laser shadowgraphy, and machine current B-dot loops. Experimental growth rates for MRT on both sides of the ablated aluminum plasma slab were comparable for centered-foils. The MRT growth rate was fastest (98 ns e-folding time) for the foil-offset case where there was a larger magnetic field to accelerate the plasma. Other cases showed slower growth rates with e-folding times of about ∼106 ns. An interpretation of the experimental data in terms of an analytic MRT model is attempted.