Development of a Portable 950 keV X‐band Linac for NDT

2009 
We are developing a portable 950 keV X‐band (9.4 GHz) linac X‐ray source for on‐site nondestructive testing of erosion of metal pipes at a petrochemical complex. To develop it, we adopted a compact X‐band 9.4 GHz magnetron of 250 kW for RF generation device. The whole device, including power supply and cooling devices, were also downsized. The dose rate of X‐ray converted in a tungsten target is designed to be 0.2 Gy/min at 1‐m distance. We designed an accelerating tube that uses the π mode for the lower energy part and the π/2 mode cavity for the higher energy. We manufactured the accelerating tube and carried out beam acceleration tests, confirming that the electron beam was accelerated up to 950 keV.